Home
Product Catalog
News
Contact Us

Product Catalog 

12v65ah Valve regulated lead acid battery

Model No.︰Np1265
Brand Name︰protettore
Country of Origin︰China
Unit Price︰US $ 67 / pc
Minimum Order︰100 pc
Share on:

 Total 20 Related Items 
Prev56789Next

Product Description

                        Description of 12v65ah battery

Application

Maintenance free storage battery 12V65ah is used for UPS power, solar system, high magnetic hanging equipment ,EPS and so on.

 

Advantage

1. The battery is full of power when its out of factory, no need to use liquid charge;

2. no memory, no need to discharge battery use, suitable for circuit design;

3. by high partition, adsorption and strong;

4. there is no flowing liquid (poor liquid), does not leak acid and free Upside down,

5. comply with environmental requirements, ease of use,

6. the use of lead-calcium alloys, battery self-discharge is very low,

7. easy storage, less maintenance;

8. using ABS plastic shell and valve technology for safe use.

 

battery characteristic

Nominal voltage

12V

Nominal capacity(20h rate)

65Ah

Size

Total height

180mm

length

350mm

width

168mm

height

180mm

Weight

20.5kg

Rated capacity                       25°C(77°F)

20 hour rate(3.25A)

65Ah

 

 

5 hour rate(10.4A)

52Ah

1 hour rate(42A)

42Ah

Internal resistance

in full charge status 25°C(77°F)

6.8mΩ

Capacity at different temperature(10h)

40°C(104°F)

102%

25°C(77°F)

100%

0°C(32°F)

85%

-15°C(5°F)

65%

Self discharge     25°C(77°F)

capacity after 3 months

91%

capacity after 6 months

82%

capacity after 12 months

64%

Mode of charge (constant voltage)       25°C(77°F)

cycle-use

initial charging current less than16.5A ,                    voltage14.10-14.40V

float-use

No limit on Initial charging current

voltage13.50-13.80V

         

 

Notice

  1. Dont near the hot source and dont under the sunshine.
  2. Dont charge in the sealed container.
  3. No short circuit. It should be addition charge if you dont use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.
  4. Dont store in the space of acid gas.
  5. You should be careful and regular check when use the battery. To avoid the battery dont work. You should change the battery if the capacity is not full or has been damage, especially after one year using.
  6. Dont put the battery in the fire, or it will explode.
  7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.
  8. Dont clean the battery by using the organic solution. (e.g. petrol)
Payment Terms︰T/T
Product Image


 
Description of 12v65ah battery Application Maintenance free storage battery 12V65ah is used for UPS power, solar system, high magnetic hanging equipment ,EPS and so on. Advantage 1. The battery is full of power when it’s out of factory, no need to use liquid charge; 2. no memory, no need to discharge battery use, suitable for circuit design; 3. by high partition, adsorption and strong; 4. there is no flowing liquid (poor liquid), does not leak acid and free Upside down, 5. comply with environmental requirements, ease of use, 6. the use of lead-calcium alloys, battery self-discharge is very low, 7. easy storage, less maintenance; 8. using ABS plastic shell and valve technology for safe use. battery characteristic Nominal voltage 12V Nominal capacity(20h rate) 65Ah Size Total height 180mm length 350mm width 168mm height 180mm Weight 20.5kg Rated capacity 25°C(77°F) 20 hour rate(3.25A) 65Ah 5 hour rate(10.4A) 52Ah 1 hour rate(42A) 42Ah Internal resistance in full charge status 25°C(77°F) 6.8mΩ Capacity at different temperature(10h) 40°C(104°F) 102% 25°C(77°F) 100% 0°C(32°F) 85% -15°C(5°F) 65% Self discharge 25°C(77°F) capacity after 3 months 91% capacity after 6 months 82% capacity after 12 months 64% Mode of charge (constant voltage) 25°C(77°F) cycle-use initial charging current less than16.5A , voltage14.10-14.40V float-use No limit on Initial charging current voltage13.50-13.80V Notice 1 Don’t near the hot source and don’t under the sunshine. 2 Don’t charge in the sealed container. 3 No short circuit. It should be addition charge if you don’t use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion. 4 Don’t store in the space of acid gas. 5 You should be careful and regular check when use the battery. To avoid the battery don’t work. You should change the battery if the capacity is not full or has been damage, especially after one year using. 6 Don’t put the battery in the fire, or it will explode. 7 Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte. 8 Don’t clean the battery by using the organic solution. (e.g. petrol)
Related Products
12v250ah Valve regulated Lead calcium battery
12v250ah Valve regulated Lead calcium battery
US $ 230
12v200ah Valve regulated lead acid battery
12v200ah Valve regulated lead acid battery
US $ 178
12v150ah Valve regulated lead acid battery
12v150ah Valve regulated lead acid battery
US $ 137
12v120ah Valve regulated lead acid battery
12v120ah Valve regulated lead acid battery
US $ 117




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !