12v33ah Valve regulated lead acid battery

Model No.︰Np1233
Brand Name︰protettore
Country of Origin︰China
Unit Price︰US $ 34 / pc
Minimum Order︰100 pc
Share on:

 Total 20 Related Items 
Prev89101112Next

Product Description

                           Description of 12v33ah battery

Advantage

1.The battery is full of power when its out of factory, no need to use liquid charge;

2.no memory, no need to discharge battery use, suitable for circuit design;

3.by high partition, adsorption and strong;

4.there is no flowing liquid (poor liquid), does not leak acid and free Upside down,

5.comply with environmental requirements, ease of use,

6.the use of lead-calcium alloys, battery self-discharge is very low,

7.easy storage, less maintenance;

8.using ABS plastic shell and valve technology for safe use.

 

Application

The VRLA battery 12v33ah can be used in UPS, light, magnetic lifting equipment ,EPS,solar system and so on.

 

battery characteristic

Nominal voltage

12V

Nominal capacity(20h rate)

33Ah

Size

Total height

156mm

length

195mm

width

130mm

height

154mm

Weight

9.5kg

Rated capacity                       25(77)

20 hour rate

33Ah

10 hour rate

30Ah

5 hour rate

28Ah

1 hour rate

19.8Ah

Internal resistance

in full charge status 25(77℉)

11.2mΩ

Capacity at different temperature(10h)

40(104)

102%

25(77)

100%

0(32)

85%

15(5)

65%

Self discharge     25(77)

capacity after 3 months

91%

capacity after 6 months

82%

capacity after 12 months

64%

Mode of charge (constant voltage)       25(77)

cycle-use

initial charging current less than16.5A ,                    voltage14.10-14.40V

float-use

No limit on Initial charging current  voltage13.50-13.80V

         

 

 

 

 Notice

  1. Dont near the hot source and dont under the sunshine.
  2. Dont charge in the sealed container.
  3. No short circuit. It should be addition charge if you dont use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.
  4. Dont store in the space of acid gas.
  5. You should be careful and regular check when use the battery. To avoid the battery dont work. You should change the battery if the capacity is not full or has been damage, especially after one year using.
  6. Dont put the battery in the fire, or it will explode.
  7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.
  8. Dont clean the battery by using the organic solution. (e.g. petrol)
Payment Terms︰T/T
Product Image


 
Description of 12v33ah battery Advantage 1.The battery is full of power when it’s out of factory, no need to use liquid charge; 2.no memory, no need to discharge battery use, suitable for circuit design; 3.by high partition, adsorption and strong; 4.there is no flowing liquid (poor liquid), does not leak acid and free Upside down, 5.comply with environmental requirements, ease of use, 6.the use of lead-calcium alloys, battery self-discharge is very low, 7.easy storage, less maintenance; 8.using ABS plastic shell and valve technology for safe use. Application The VRLA battery 12v33ah can be used in UPS, light, magnetic lifting equipment ,EPS,solar system and so on. battery characteristic Nominal voltage 12V Nominal capacity(20h rate) 33Ah Size Total height 156mm length 195mm width 130mm height 154mm Weight 9.5kg Rated capacity 25℃(77℉) 20 hour rate 33Ah 10 hour rate 30Ah 5 hour rate 28Ah 1 hour rate 19.8Ah Internal resistance in full charge status 25℃(77℉) 11.2mΩ Capacity at different temperature(10h) 40℃(104℉) 102% 25℃(77℉) 100% 0℃(32℉) 85% ﹣15℃(5℉) 65% Self discharge 25℃(77℉) capacity after 3 months 91% capacity after 6 months 82% capacity after 12 months 64% Mode of charge (constant voltage) 25℃(77℉) cycle-use initial charging current less than16.5A , voltage14.10-14.40V float-use No limit on Initial charging current voltage13.50-13.80V Notice 1 Don’t near the hot source and don’t under the sunshine. 2 Don’t charge in the sealed container. 3 No short circuit. It should be addition charge if you don’t use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion. 4 Don’t store in the space of acid gas. 5 You should be careful and regular check when use the battery. To avoid the battery don’t work. You should change the battery if the capacity is not full or has been damage, especially after one year using. 6 Don’t put the battery in the fire, or it will explode. 7 Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte. 8 Don’t clean the battery by using the organic solution. (e.g. petrol)
Related Products
12v250ah Valve regulated Lead calcium battery
12v250ah Valve regulated Lead calcium battery
US $ 230
12v200ah Valve regulated lead acid battery
12v200ah Valve regulated lead acid battery
US $ 178
12v150ah Valve regulated lead acid battery
12v150ah Valve regulated lead acid battery
US $ 137
12v120ah Valve regulated lead acid battery
12v120ah Valve regulated lead acid battery
US $ 117




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !